iMist, one of the UK’s foremost suppliers of high-pressure water-mist fire-suppression techniques, has labored with main trade physique the Fire Protection Association (FPA), to help it acquire UKAS accreditation for certainly one of its fire-testing laboratory amenities – becoming the primary and only test facility within the UK to carry this accreditation.
The fast-growing Hull-headquartered enterprise, which has developed its own vary of high-pressure water-mist fire-suppression systems, assisted the FPA in gaining UKAS accreditation for its BS8458: 2015 Annex C fire testing in Blockley, Gloucestershire, which is certainly one of the most comprehensive hearth test and research operations in the UK. IMist offered the FPA with its proprietary pumps, pipework, hoses, clips and nozzles in addition to the assist of iMist’s skilled team.
The UKAS accreditation of the FPA’s BS 8458 Annex C fire testing marks one other essential milestone in the growth of water-mist systems within the UK.
Alex Pollard, operations director of iMist, comments: ‘For over seventy five years, the FPA has been on the forefront of fireplace safety and we’re proud to have assisted them in achieving this revered third-party accreditation. It is a further demonstration of the rising significance of high-pressure water-mist methods in tackling the current challenges facing the fire-suppression sector. Not solely do they use significantly less water than conventional sprinkler systems, they’re also simpler and faster to put in and, thereby, more cost effective.’
As part of its ongoing R&D product testing programme, iMist has also undertaken a collection of stay hearth testing on the FPA’s UKAS accredited laboratory, which has elevated the system’s purposes, demonstrating that in addition to being put in within the cavity above the ceiling, the iMist system pipework can safely and effectively be put in under a plasterboard ceiling.
For the reside hearth checks, the iMist nozzle was fed by each flexible and solid pipework operating under a normal plasterboard ceiling. In every of the exams, the gas load was ignited and the heat from the hearth triggered the bulb within the nozzle to burst, which activated the iMist high-pressure water-mist system, discharging the fantastic water-mist particles at excessive pressure for 30 minutes. During this time, the temperatures at predetermined heights in the check cell have been measured by thermocouples. At no level during any of the tests had been any of the Annex C temperature limits breached and the entire fires have been efficiently suppressed.
pressure gauge weksler ราคา , iMist business growth director, added: ‘While hearth system pipework is normally put in in the cavity above a ceiling, in some properties, particularly in older tower blocks, there are frequent points around the attainable break-up of asbestos hidden in ceiling materials. Our newest indicative checks show that the housing industry can now explore one other less disruptive and highly effective possibility by installing a water-mist system under the present ceiling. Given the growing must retrospectively match fire-suppression methods to have the ability to meet the latest regulatory requirements and produce older housing stock up to present standards, that is great information for each landlords and developers.’
For extra information: imist.com